GeneralNyxorWidget
0
0
500
555
Form
-
-
nX Control Register
9
9
-
nXyter Control Register value, below the bits are shown
-
reset for nXyter time stamp counter
Reset NX time stamp counter
-
Reset of data receiver (only for testing)
Reset data receiver
-
Enabling of Acquisition Trigger as Test Trigger.
Acquisition trigger as test trigger
-
Enabling of the second nXyter’s Receiver
Second NX Receiver enabled
-
Not Acquisition Trigger generating.
No acquisition Trigger generating
-
Test Pulse and Acquisition Trigger generating
Test pulse and acquisition trigger
-
Enabling of nXyter’s receiver in test mode.
NX Receiver test mode
-
Enable of nXyter’s receiver core.
NX Receiver enabled
-
Gain control for nXyter 1
NX0 Gain Control
-
Gain control for nXyter 2.
NX1 Gain Control
-
Eabling of synch pulse for nXyter 1
NX0 Synch pulse
-
Enabling of synch pulse for nXyter 2
NX1 Synch pulse
-
. Enabling of test code for nXyter (no need from nXyter).
TestCode NXyters
-
Enabling of test code for ADC (no need from nXyter).
TestCode ADC
-
Qt::Vertical
20
40
-
-
Trigger Window
-
-
Pre
Qt::AlignCenter
-
Post
Qt::AlignCenter
-
-
Pre-Trigger Window register value
-
Post-Trigger Window register value
-
-
Pre-Trigger time in nanoseconds
ns
128000.000000000000000
31.250000000000000
-
Post-Trigger time in nanoseconds
ns
128000.000000000000000
31.250000000000000
-
Delays
-
-
STPD
Qt::AlignCenter
-
TATD
Qt::AlignCenter
-
-
nXyter Delay Register 1 (Second Test Pulse Delay)
-
nXyter Delay Register 2 (Test Acquisition Trigger Delay).
-
-
Second Test Pulse Delay in nanoseconds
ns
128000.000000000000000
31.250000000000000
-
Test Acquisition Trigger Delay in nanoseconds
ns
128000.000000000000000
31.250000000000000
-
Test Codes
-
-
ADC
Qt::AlignCenter
-
NX code 1
Qt::AlignCenter
-
NX code 2
Qt::AlignCenter
-
-
<html><head/><body><p>nXyter ADC’s Test Code (NYXOR Self-Test Mode).</p><p><span style=" font-weight:600;">Note</span>: When ESelfTest = ‘1’ (nXyter Control Register - TestCodeADC), then the code written in this register is provided as “ADC Data” (only in Self-Test Mode for NYXOR).</p><p><br/></p></body></html>
-
<html><head/><body><p>nXyter’s Test Code 1 (NYXOR Self-Test Mode).</p><p><span style=" font-weight:600;">Note: </span>When ESelfTest = ‘1’ (nXyter Control Register- TestCodeNXyters), then the code written in this register is used to emulate the data coming from nXyter (<span style=" font-weight:600;">only in Self-Test Mode for NYXOR</span>).</p><p><br/></p></body></html>
-
<html><head/><body><p>nXyter’s Test Code 2 (NYXOR Self-Test Mode).</p><p><span style=" font-weight:600;">Note: </span>When ESelfTest = ‘1’ (nXyter Control Register- TestCodeNXyters), then the code written in this register is used to emulate the data coming from nXyter (<span style=" font-weight:600;">only in Self-Test Mode for NYXOR</span>).</p><p><br/></p></body></html>
-
Qt::Vertical
20
40