GeneralNyxorWidget 0 0 500 555 Form nX Control Register 9 9 nXyter Control Register value, below the bits are shown reset for nXyter time stamp counter Reset NX time stamp counter Reset of data receiver (only for testing) Reset data receiver Enabling of Acquisition Trigger as Test Trigger. Acquisition trigger as test trigger Enabling of the second nXyter’s Receiver Second NX Receiver enabled Not Acquisition Trigger generating. No acquisition Trigger generating Test Pulse and Acquisition Trigger generating Test pulse and acquisition trigger Enabling of nXyter’s receiver in test mode. NX Receiver test mode Enable of nXyter’s receiver core. NX Receiver enabled Gain control for nXyter 1 NX0 Gain Control Gain control for nXyter 2. NX1 Gain Control Eabling of synch pulse for nXyter 1 NX0 Synch pulse Enabling of synch pulse for nXyter 2 NX1 Synch pulse . Enabling of test code for nXyter (no need from nXyter). TestCode NXyters Enabling of test code for ADC (no need from nXyter). TestCode ADC Qt::Vertical 20 40 Trigger Window Pre Qt::AlignCenter Post Qt::AlignCenter Pre-Trigger Window register value Post-Trigger Window register value Pre-Trigger time in nanoseconds ns 128000.000000000000000 31.250000000000000 Post-Trigger time in nanoseconds ns 128000.000000000000000 31.250000000000000 Delays STPD Qt::AlignCenter TATD Qt::AlignCenter nXyter Delay Register 1 (Second Test Pulse Delay) nXyter Delay Register 2 (Test Acquisition Trigger Delay). Second Test Pulse Delay in nanoseconds ns 128000.000000000000000 31.250000000000000 Test Acquisition Trigger Delay in nanoseconds ns 128000.000000000000000 31.250000000000000 Test Codes ADC Qt::AlignCenter NX code 1 Qt::AlignCenter NX code 2 Qt::AlignCenter <html><head/><body><p>nXyter ADC’s Test Code (NYXOR Self-Test Mode).</p><p><span style=" font-weight:600;">Note</span>: When ESelfTest = ‘1’ (nXyter Control Register - TestCodeADC), then the code written in this register is provided as “ADC Data” (only in Self-Test Mode for NYXOR).</p><p><br/></p></body></html> <html><head/><body><p>nXyter’s Test Code 1 (NYXOR Self-Test Mode).</p><p><span style=" font-weight:600;">Note: </span>When ESelfTest = ‘1’ (nXyter Control Register- TestCodeNXyters), then the code written in this register is used to emulate the data coming from nXyter (<span style=" font-weight:600;">only in Self-Test Mode for NYXOR</span>).</p><p><br/></p></body></html> <html><head/><body><p>nXyter’s Test Code 2 (NYXOR Self-Test Mode).</p><p><span style=" font-weight:600;">Note: </span>When ESelfTest = ‘1’ (nXyter Control Register- TestCodeNXyters), then the code written in this register is used to emulate the data coming from nXyter (<span style=" font-weight:600;">only in Self-Test Mode for NYXOR</span>).</p><p><br/></p></body></html> Qt::Vertical 20 40