// pipe for SIS100 hadron setup // by DE, 20131007 // // pipe_v13c.geo // ----------------- // this is a copy of pipe_standard.geo, // with changes as follows: // - reduce diameter of segment 3, now starting at 4500 mm // to 33 cm to avoid overlap with tof // - fill empty section at RICH position for SIS100 hadron setup // // description of shape PCON: // - material // - number of points // - azimuthal angle from xxx to yyy [deg] // - point 1: z inner-radius outer-radius [mm] // - ... // - point n // //---------------------------------------------------------- pipe1 cave PCON carbon 9 0. 360. -50. 25. 25.5 25. 25. 25.5 35. 130. 130.5 239.5 130. 130.5 240. 128. 130.5 269.5 10. 12.5 270. 10. 10.5 1600. 32. 32.5 3500. 200. 200.5 0. 0. 0. 1. 0. 0. 0. 1. 0. 0. 0. 1 // pipevac1 cave PCON vacuum 9 0. 360. -50. 0. 25. 25. 0. 25. 35. 0. 130. 239.5 0. 130. 240. 0. 128. 269.5 0. 10. 270. 0. 10. 1600. 0. 32. 3500. 0. 200. 0. 0. 0. 1. 0. 0. 0. 1. 0. 0. 0. 1 // pipe2 cave PCON carbon 2 0. 360. 3500. 200. 200.5 4500. 200. 200.5 0. 0. 0. 1. 0. 0. 0. 1. 0. 0. 0. 1 pipevac2 pipe2 PCON vacuum 2 0. 360. 3500. 0. 200. 4500. 0. 200. 0. 0. 0. 1. 0. 0. 0. 1. 0. 0. 0. 1 // pipe3 cave PCON carbon 2 0. 360. 4500. 149. 149.5 10000. 149. 149.5 0. 0. 0. 1. 0. 0. 0. 1. 0. 0. 0. 1 pipevac3 pipe3 PCON vacuum 2 0. 360. 4500. 0. 149. 10000. 0. 149. 0. 0. 0. 1. 0. 0. 0. 1. 0. 0. 0. 1