################################################################# # Digitization parameters for MVD # Format: # parameter_name:parameter_type(i-integer, d-double) parameter_value # PndMvdDigiPar # Description of parameters: ################################################################# ################################################################# # Digitization parameters for RECTANGULAR Mvd strip sensors ################################################################# # threshold set to 5*sigmaNoise (noise rate ~ DPM signals rate) [MVDStripDigiParRect] top_pitch:Double_t 0.0130 bot_pitch:Double_t 0.0130 orient:Double_t 1.570796327 skew:Double_t -1.570796327 top_anchor_x:Double_t -3.3345 top_anchor_y:Double_t 1.6705 bot_anchor_x:Double_t -3.3345 bot_anchor_y:Double_t 1.6705 nr_fe_channels:Int_t 128 nr_fe_top:Int_t 4 nr_fe_bottom:Int_t 2 charge_threshold:Double_t 5000 charge_noise:Double_t 1000 QCloudSigma:Double_t 0.0008 sens_Type:Text_t Rect fe_Type:Text_t APV25 fe_BusClock:Double_t 30 cluster_mod:Int_t 0 cluster_mean:Int_t 1 cluster_radchan:Int_t 2 cluster_radtime:Int_t 0 cluster_corrchargecut:Double_t 12000. cluster_singlechargecut:Double_t 3000. chargeconv_method:Int_t 1 ################################################################# # Digitization parameters for TRAPEZOID Mvd strip sensors ################################################################# # threshold set to 5*sigmaNoise (noise rate ~ DPM signals rate) [MVDStripDigiParTrap] top_pitch:Double_t 0.00675 bot_pitch:Double_t 0.00675 orient:Double_t 1.439896633 skew:Double_t 0.261799388 top_anchor_x:Double_t -1.72967 top_anchor_y:Double_t 2.78327 bot_anchor_x:Double_t -1.72967 bot_anchor_y:Double_t 2.78327 nr_fe_channels:Int_t 128 nr_fe_top:Int_t 4 nr_fe_bottom:Int_t 4 charge_threshold:Double_t 5000 charge_noise:Double_t 1000 QCloudSigma:Double_t 0.0008 sens_Type:Text_t Trap fe_Type:Text_t APV25 fe_BusClock:Double_t 30 cluster_mod:Int_t 0 cluster_mean:Int_t 1 cluster_radchan:Int_t 2 cluster_radtime:Int_t 0 cluster_corrchargecut:Double_t 12000. cluster_singlechargecut:Double_t 3000. chargeconv_method:Int_t 1 ################################################################# # Digitization parameters for RECTANGULAR double-sided # strip sensors used in the tracking station. ################################################################# # threshold set to 5*sigmaNoise (noise rate ~ DPM signals rate) [MVDStripDigiParTD] top_pitch:Double_t 0.0050 bot_pitch:Double_t 0.0050 orient:Double_t 1.570796327 skew:Double_t -1.570796327 top_anchor_x:Double_t -0.9575 top_anchor_y:Double_t 0.9575 bot_anchor_x:Double_t -0.9575 bot_anchor_y:Double_t 0.9575 nr_fe_channels:Int_t 128 nr_fe_top:Int_t 3 nr_fe_bottom:Int_t 3 charge_threshold:Double_t 5000 charge_noise:Double_t 1000 QCloudSigma:Double_t 0.0008 sens_Type:Text_t TD fe_Type:Text_t APV25 fe_BusClock:Double_t 30 cluster_mod:Int_t 0 cluster_mean:Int_t 0 cluster_radchan:Int_t 2 cluster_radtime:Int_t 0 cluster_corrchargecut:Double_t 1200. cluster_singlechargecut:Double_t 1000. chargeconv_method:Int_t 0 ################################################################# # Digitization parameters for RECTANGULAR single-sided # strip sensors used in the tracking station. ################################################################# # threshold set to 5*sigmaNoise (noise rate ~ DPM signals rate) [MVDStripDigiParTS] top_pitch:Double_t 0.0050 bot_pitch:Double_t 1.9200 orient:Double_t 1.570796327 skew:Double_t -1.570796327 top_anchor_x:Double_t -0.9575 top_anchor_y:Double_t 0.9575 bot_anchor_x:Double_t 0. bot_anchor_y:Double_t 0.9575 nr_fe_channels:Int_t 128 nr_fe_top:Int_t 3 nr_fe_bottom:Int_t 1 charge_threshold:Double_t 5000 charge_noise:Double_t 1000 QCloudSigma:Double_t 0.0008 sens_Type:Text_t TS fe_Type:Text_t APV25 fe_BusClock:Double_t 30 cluster_mod:Int_t 0 cluster_mean:Int_t 0 cluster_radchan:Int_t 2 cluster_radtime:Int_t 0 cluster_corrchargecut:Double_t 1200. cluster_singlechargecut:Double_t 1000. chargeconv_method:Int_t 0 ################################################################# # Digitization Parameters for MVD Pixel ################################################################# # threshold set to 6 sigma (noise rate ~ DPM signals rate) [MVDPixelDigiPar] dimX:Double_t 0.0100 dimY:Double_t 0.0100 threshold:Double_t 1000 noise:Double_t 200 QCloudSigma:Double_t 0.0008 FECols:Int_t 110 FERows:Int_t 116 ClustRad:Double_t 1.8 fe_BusClock:Double_t 155.52 chargeconv_method:Int_t 1 PixelSorterCellWidth:Double_t 10 PixelSorterNumberOfCells:Int_t 1000 ################################################################# ################################################################# # Charge to Tot Digitization parameters for MVD # parameter_name:parameter_type(i-integer, d-double) parameter_value # PndMvdTotDigiPar ################################################################# # Digitization Parameters for MVD Pixel ################################################################# [MVDPixelTotDigiPar] charge_time:Double_t 100 const_current:Double_t 60 clock_frequency:Double_t 50 ################################################################# ################################################################# # Digitization parameters for RECTANGULAR Mvd strip sensors ################################################################# [MVDStripTotDigiParRect] charge_time:Double_t 100. const_current:Double_t 60. clock_frequency:Double_t 50. ################################################################# # Digitization parameters for TRAPEZOID Mvd strip sensors ################################################################# [MVDStripTotDigiParTrap] charge_time:Double_t 100. const_current:Double_t 60. clock_frequency:Double_t 50. ################################################################# # Digitization parameters for RECTANGULAR double-sided # strip sensors used in the tracking station. ################################################################# [MVDStripTotDigiParTD] charge_time:Double_t 100. const_current:Double_t 60. clock_frequency:Double_t 50. ################################################################# # Digitization parameters for RECTANGULAR single-sided # strip sensors used in the tracking station. ################################################################# [MVDStripTotDigiParTS] charge_time:Double_t 100. const_current:Double_t 60. clock_frequency:Double_t 50. ################################################################# [MVDStriDummy] charge_time:Double_t 100. const_current:Double_t 60. clock_frequency:Double_t 50. #################################################################